API 5L Pipe Specification

API 5L specification (API Spec 5L, Line Pipe) is the buying and manufacturing rulebook for steel line pipe used in pipeline transportation systems. The current edition is the 47th edition (published June 2026; Monogram Program effective date 1 July 2027 per API advisory). This page is the specification hub: PSL1 vs PSL2, grade map, tolerances and RFQ language. Detailed chemistry and strength for individual grades live on the grade pages — we deep-link them and do not try to rank as those grade primaries.

Hub map. Grade B / L245 → API 5L Grade B. X52 / L360 → API 5L X52. X65 / L450 → API 5L X65. Process products: seamless, ERW/HFW, LSAW, SSAW.

Ordering line pipe. Send grade × PSL × OD/wall or NPS/schedule × process × quantity × destination. Partner mill named on the quote; mill EN 10204 certificates forwarded unaltered.

Request a quotation WhatsApp

Mejor Steel is an export trading company in Anyang, China — not an API monogram pipe mill. We place orders with partner mills that manufacture to Spec 5L, name the producing mill on the quotation, and forward the mill’s inspection documents with the shipment. See How we supply, EN 10204 3.1 vs 3.2, MTC guide.

Edition note (2026-11-07): API announced the 47th edition of Spec 5L on 2 June 2026. Many POs still reference the 46th edition (2018) until project documents flip. State the edition on every RFQ. Figures on grade pages follow the soft-metric values we verified for those grades; confirm against the edition named on your PO.

API 5L at a glance (47th edition)

Item47th edition (June 2026)
Full titleAPI Specification 5L, Line Pipe
PublishedJune 2, 2026; 206 pages
Replaces46th edition (April 2018)
API Monogram effective dateJuly 1, 2027
Product levelsPSL 1, PSL 2
Pipe typesSMLS, CW, LFW, HFW, LW, SAWL, SAWH, COWL, COWH
Outside diameter range (Table 9)10.3 mm (0.405 in) to 2134 mm (84 in)
Max wall in Table 952.0 mm (2.050 in) for D ≥ 711 mm
GradesPSL 1: L175/A25 to L485/X70. PSL 2: L245/B to L830M/X120M
Grade suffix (PSL 2)R as-rolled, N normalized, Q quenched & tempered, M thermomechanical
Service annexesG fracture arrest, H sour (classes A, L, F), J offshore, N strain-based design
Companion standardISO 3183 (line pipe, same technical base)

What changed in the 47th edition (vs the 46th)

Most supplier pages still describe the 46th edition (2018). The 47th edition lists more than 15 changed topic areas. The ones that change what a buyer writes on a purchase order:

Topic47th-edition requirementWhy it matters on an order
Sour service classesAnnex H now has sour class A (NACE TM0284 Solution A), L (moderate sour, Solution C at 1 psi H₂S, pH 4.0) and F (purchaser-defined). The class letter follows the grade, e.g. X52MSA.“PSL 2 sour” is no longer a complete specification — the PO must state A, L or F.
Sour max tensileTable H.2 sets X65QS/MS Rm max 685 MPa and X70QS/MS 720 MPa — well below the 760 MPa max for the same grades in non-sour PSL 2 (Table 7).Mill test certificates from older stock can fail the new ceiling.
CO₂ pipelinesAnnex G now covers gas-phase and denser-than-gas-phase CO₂ lines; for dense-phase CO₂ the arrest toughness is set by full-scale burst testing.Adds a test programme and lead time to CCS line pipe.
RecordsManufacturer keeps test records (chemistry, tensile, CVN, DWT, hydrotest charts, NDT) at least 5 years after the purchase date (§13.1).Ask for this in the contract if your project retention is longer.
HFW weld qualityRevised HFW quality and weld Charpy retest options (Figure 10).Relevant to every ERW/HFW order.
LaminationsUltrasonic lamination testing updated; Annex H lists lamination UT for sour class L or F pipe with t ≥ 5.0 mm as an order item.State lamination UT on sour PSL 2 orders.
Magnetic particleMT of pipe ends referenced to ISO 10893-5 or ASTM E3024 (instead of ASTM E709 alone).Update inspection plans and ITPs.
Hydrotest gaugesCalibration requirements for pressure-measuring devices added.Ask for calibration records at FAT/inspection.
MonogramAPI Monogram licensing rules moved out of 5L into API Q1 (Annex A of Q1).Monogrammed pipe is still marked “API Spec 5L”; licensing is checked through API’s Composite List.
Also revisedNDE personnel certification, flattening test, microalloy chemistry, subsize Charpy, SSC guidance for TMCP plate, local hard zones.—

Which edition does my order use? The one written on the purchase order. Publication of a new edition does not change an existing contract. For new orders we quote to the 47th edition unless your project specification names the 46th.

Pipe grades and delivery conditions

An API 5L grade name has two forms: L + minimum yield in MPa (ISO style, e.g. L360) or X + minimum yield in ksi (US style, e.g. X52). For PSL 2 the suffix letter is part of the grade:

SuffixDelivery conditionTypical use
RAs-rolled (PSL 2 only for B and X42)Low-grade PSL 2
NNormalizing rolled, normalized, normalized and temperedSeamless and ERW up to X60N
QQuenched and temperedSeamless, heavy wall, up to X100Q (X90Q/X100Q seamless only)
MThermomechanical rolled or formedWelded pipe from TMCP plate/coil, up to X120M
SSour service (Annex H), followed by class A/L/Fe.g. X65QSA
OOffshore service (Annex J)e.g. X65MO

PSL 1 grades: L175/A25, L175P/A25P, L210/A, L245/B, L290/X42, L320/X46, L360/X52, L390/X56, L415/X60, L450/X65, L485/X70.

PSL 2 grades: BR, X42R; BN–X60N; BQ–X100Q; BM–X120M (see Table 1 of the 47th edition for the exact list per delivery condition).

Reading a grade designation

Designation partExampleMeaning
L + numberL450ISO-style name; number = minimum yield in MPa
X + numberX65API-style name; number = minimum yield in ksi (65 ksi ≈ 448 MPa, the standard rounds to 450 MPa)
A25 / A / BGrade BLegacy low grades: 172 / 207 / 245 MPa minimum yield
P suffix (PSL 1)A25PRephosphorized, for threaded pipe only (P 0.045–0.080 %)
R / N / Q / M (PSL 2)X52NDelivery condition: as-rolled, normalized, quenched and tempered, thermomechanical
S suffixX65QSAnnex H sour service
O suffixX65QOAnnex J offshore
PSL markingPSL 2Product specification level, stencilled after the grade

Both naming systems describe the same steel. Write one on the purchase order, either X65Q or L450Q, and the mill will usually stencil both.

Which pipe types are allowed for each grade (Table 2)

TypePSL 1 B / X42–X70PSL 2 B–X80PSL 2 above X80
SMLS (seamless)YesYesUp to X100
HFW (ERW)YesYesNo
LFW, CWLFW yes, CW only A25/A25PNoNo
LW (laser)X42–X70 onlyNoNo
SAWL (LSAW) / SAWH (SSAW)YesYesYes, to X120
COWL / COWHYesYesNo

Helical-seam pipe (SAWH/SSAW) starts at D ≥ 114.3 mm; double-seam pipe only at D ≥ 914 mm; threaded ends only up to 508 mm and only PSL 1.

How each PSL 2 delivery condition is made (Table 3)

Pipe typeStarting materialForming / heat treatmentDelivers
SMLSBillet, bloom or ingotAs-rolledR
SMLSBilletNormalizing forming, or hot forming + normalizingN
SMLSBilletHot forming (or + cold finishing) + quench & temperQ
HFWNormalizing rolled coilCold forming + weld-area heat treatmentN
HFWThermomechanical rolled coilCold forming + weld-area heat treatment (± stress relief of whole pipe)M
HFWCoilCold forming + full-body normalizing or Q&TN or Q
SAW / COWNormalized or normalizing rolled plate/coilCold formingN
SAW / COWThermomechanical rolled plate/coilCold formingM
SAW / COWQ&T plate, or plate + pipe Q&TCold formingQ

Practical reading: most LSAW and SSAW X60–X80 is “M” (TMCP plate or coil); heavy-wall seamless X65–X70 is “Q”; small-bore ERW for gathering lines is often “N” or “M” with weld-seam heat treatment.

PSL 1 vs PSL 2 — the differences that cost money

RequirementPSL 1PSL 2
SMLS pipe-body NDTOnly if agreed (mandatory for Q&T Grade B)100 % full length (Annex E, Table E.2)
Weld seam NDT (D ≥ 60.3 mm)100 % full length100 % full length
Inspection documentOnly if agreed (3.1 or 3.2)3.1 mandatory; 3.2 if ordered
EndsPlain, threaded, belled or specialPlain end only
Max yield and max tensileNot specifiedSpecified (e.g. X52: YS 360–530 MPa, UTS 460–760 MPa)
Yield/tensile ratioNot specified≤ 0.93 up to X80
Charpy (CVN) pipe bodyNot mandatoryMandatory; e.g. 27 J min (≤ X70, D ≤ 762 mm) at 0 °C
P / S max0.030 / 0.030 %0.025 / 0.015 %
Carbon equivalentNot specifiedCEIIW ≤ 0.43, CEPcm ≤ 0.25 (most grades)
TraceabilityHeat and test-unit identity kept until tests passAny length traceable to its test unit and results
DWT testNoIf agreed, welded pipe D ≥ 508 mm; ≥ 85 % shear area at 0 °C
Manufacturing procedure qualification (Annex B)NoWhen ordered

Rule of thumb: if your design code, client or route includes sour gas, offshore, low temperature or high-pressure gas transmission, you need PSL 2. Most gas transmission projects and EPC tenders specify PSL 2 as standard. For a deeper comparison see API 5L PSL1 vs PSL2.

How to choose PSL, grade and pipe type (decision guide)

Project conditionTypical choiceWhy
Water, air, low-pressure utility or structural linePSL 1, Grade B or X42, ERW or SMLSNo CVN, no max yield, lowest cost and fastest mill slot
Onshore gas transmission under ASME B31.8 or 49 CFR 192PSL 2, X52–X70, HFW (≤ 24 in) or LSAW/SSAW (larger)Fracture toughness, max yield and CE control are needed for girth welding and crack arrest
Onshore crude/products under ASME B31.4PSL 2, X52–X65Same toughness logic; operators’ specs nearly always call PSL 2
Wet H₂S (sour) servicePSL 2 Annex H, grade suffix S (e.g. X52MS, X65QS)Adds HIC/SSC testing, 250 HV10 hardness cap and low S
Subsea / offshore riser or flowlinePSL 2 Annex J, suffix O (e.g. X65QO)Tighter dimensions, hardness and NDT; Annex H can be added for sour subsea service
Strain-based design, seismic or permafrost routePSL 2 Annex N plus purchaser specLongitudinal strain capacity, Y/T and uniform elongation by agreement
Small-bore, high-pressure, thick wall (≤ 16 in)SMLS, PSL 2 Q (quenched and tempered)No seam; Q route gives toughness through thick walls
Large diameter (≥ 26 in) at volumeLSAW (JCOE/UOE) or SSAWSeamless is unavailable or uneconomic above about 24 in

Rules of thumb that save rework:

  • Grade substitution needs approval. Clause 9.1 says pipe made as X60 or higher cannot be shipped against an order for X52 or lower without the purchaser’s approval. PSL 2 also caps maximum yield, so an X65 heat cannot be certified as X52 PSL 2 unless its yield falls inside the X52 range of 360–530 MPa.
  • Dual-grade stencils are common in stock. Grade B/X42 or X52/X60 dual-marked pipe is valid only when the heat meets the chemistry and tensile limits of both grades.
  • Delivery-condition letter matters for welding. N (normalized) and Q (quenched and tempered) suit seamless and thick wall. M (thermomechanical rolled) gives the lowest carbon and CE for field welding, and is a welded-pipe route.
  • Wall thickness drives cost more than grade. Moving from X52 to X65 at the same pressure cuts the wall by about 20 %, so tonnage, freight and welding time all fall. See the worked example below.
  • Test temperature belongs on the PO. The PSL 2 CVN default is 0 °C. Arctic or deep-buried lines often specify −20 °C to −46 °C, and the mill must know this before it melts the steel.

Seamless vs ERW/HFW vs LSAW vs SSAW for API 5L

FactorSMLSHFW (ERW)LSAWSSAW
Usual OD range1/2–24 in2 3/8–24 in16–64 in20–100 in
Weld seamNoneLongitudinal, no fillerLongitudinal, submerged arcHelical, submerged arc
Wall tolerance (Table 11)+15 % / −12.5 % for t 4–25 mmTight (from plate/coil)TightTight
Typical PSL 2 gradesB–X70 (N/Q)B–X80 (M)B–X80+ (M)B–X80 (M)
StrengthsNo seam, thick wall, sour/HP small boreLowest cost per tonne at ≤ 24 in, good concentricityLarge OD, heavy wall, offshore and high-pressure trunklinesLowest cost at large OD, long lengths
Watch-outsEccentricity, longer lead timeSeam heat-treatment and NDT recordsExpanded-pipe ovality, end radiographyHelical seam length, residual stress; some operators exclude it for offshore

PSL 1 (Table 4), % max

GradeC seamlessC weldedMn seamlessMn weldedPS
B0.280.261.201.200.0300.030
X420.280.261.301.300.0300.030
X46 / X52 / X560.280.261.401.400.0300.030
X600.280.261.401.400.0300.030
X650.280.261.401.450.0300.030
X700.280.261.401.650.0300.030

PSL 1 grades A25 (C 0.21, Mn 0.60), A25P (C 0.21, Mn 0.60, P 0.045–0.080) and A (C 0.22, Mn 0.90) are the same for seamless and welded pipe. Cu, Ni, Cr ≤ 0.50 %, Mo ≤ 0.15 %; for Grade B, Nb + V ≤ 0.06 % unless agreed; no deliberate boron (residual ≤ 0.001 %). For each 0.01 % carbon below the maximum, Mn may rise 0.05 % (to 1.65 % for B–X52, 1.75 % above X52 and below X70, 2.00 % for X70). Nb + V + Ti ≤ 0.15 %.

PSL 2 (Table 5), all standard grades, % max

GradeCSiMnPSVNbTiCEIIWCEPcm
BR0.240.401.200.0250.015Nb+V ≤ 0.06Nb+V ≤ 0.060.040.430.25
X42R0.240.401.200.0250.0150.060.050.040.430.25
BN0.240.401.200.0250.015Nb+V ≤ 0.06Nb+V ≤ 0.060.040.430.25
X42N0.240.401.200.0250.0150.060.050.040.430.25
X46N0.240.401.400.0250.0150.070.050.040.430.25
X52N0.240.451.400.0250.0150.100.050.040.430.25
X56N0.240.451.400.0250.0150.100.050.040.430.25
X60N0.240.451.400.0250.0150.100.050.04Per orderPer order
BQ0.180.451.400.0250.0150.050.050.040.430.25
X42Q / X46Q0.180.451.400.0250.0150.050.050.040.430.25
X52Q0.180.451.500.0250.0150.050.050.040.430.25
X56Q0.180.451.500.0250.0150.070.050.040.430.25
X60Q / X65Q0.180.451.700.0250.015Nb+V+Ti ≤ 0.150.430.25
X70Q0.180.451.800.0250.015Nb+V+Ti ≤ 0.150.430.25
X80Q0.180.451.900.0250.015Nb+V+Ti ≤ 0.15Per orderPer order
X90Q / X100Q (SMLS)0.160.451.900.0200.010Nb+V+Ti ≤ 0.15Per orderPer order
BM0.220.451.200.0250.0150.050.050.040.430.25
X42M / X46M0.220.451.300.0250.0150.050.050.040.430.25
X52M / X56M0.220.451.400.0250.015Nb+V+Ti ≤ 0.150.430.25
X60M / X65M0.120.451.600.0250.015Nb+V+Ti ≤ 0.150.060.430.25
X70M0.120.451.700.0250.015Nb+V+Ti ≤ 0.150.060.430.25
X80M0.120.451.850.0250.015Nb+V+Ti ≤ 0.150.060.430.25
X90M / X100M / X120M0.100.552.100.0200.010Nb+V+Ti ≤ 0.150.06—0.25

Footnote limits that buyers check on the MTC (Table 5, 47th edition):

RuleApplies toLimit
Cu / Ni / Cr / MoBR–X56N, BQ–X56Q, BM–X56M0.50 / 0.30 / 0.30 / 0.15 %
Cu / Ni / Cr / MoX60N, X60Q–X70Q, X60M–X120M0.50 / 0.50 / 0.50 / 0.50 %
Cu / Ni / Cr / MoX80Q0.50 / 1.00 / 0.50 / 0.50 %
Cu / Ni / Cr / MoX90Q, X100Q0.50 / 1.00 / 0.55 / 0.80 %
BoronX80Q–X100Q≤ 0.004 %
BoronAll other PSL 2No intentional addition; residual ≤ 0.001 %
C + NbX60M–X120M≤ 0.20 %
Al total / NX60M–X120M≤ 0.070 % / ≤ 0.015 %
Mn increase per 0.01 % C below maxAll+0.05 % Mn, to 1.65 % (≤ X52), 1.75 % (> X52, < X70), 2.00 % (X70–X80), 2.20 % (> X80)
CE for seamless t > 20.0 mmSMLSPer order
Chemistry for t > 25.0 mmAllPer order

CEIIW applies when C > 0.12 %, CEPcm when C ≤ 0.12 % (product analysis). CEIIW = C + Mn/6 + (Cr + Mo + V)/5 + (Ni + Cu)/15; CEPcm = C + Si/30 + Mn/20 + Cu/20 + Ni/60 + Cr/20 + Mo/15 + V/10 + 5B. Thicker walls (t > 25 mm) and sour pipe (Annex H) have their own agreed or tighter limits — we put them on the quotation.

Tensile properties

PSL 1 (Table 6), minimum

GradeYield, MPa (psi)Tensile, MPa (psi)
A210 (30,500)335 (48,600)
B245 (35,500)415 (60,200)
X42290 (42,100)415 (60,200)
X46320 (46,400)435 (63,100)
X52360 (52,200)460 (66,700)
X56390 (56,600)490 (71,100)
X60415 (60,200)520 (75,400)
X65450 (65,300)535 (77,600)
X70485 (70,300)570 (82,700)

PSL 2 (Table 7), min–max

GradeYield, MPaTensile, MPaYS/TS max
BR/BN/BQ/BM245–450415–6550.93
X42R/N/Q/M290–495415–6550.93
X46N/Q/M320–525435–6550.93
X52N/Q/M360–530460–7600.93
X56N/Q/M390–545490–7600.93
X60N/Q/M415–565520–7600.93
X65Q/M450–600535–7600.93
X70Q/M485–635570–7600.93
X80Q/M555–705625–8250.93
X90M625–775695–9150.95
X100M690–840760–9900.97
X120M830–1050915–11450.99

Minimum elongation is not a fixed number: it is calculated from the test-piece area and the grade’s tensile strength (Af = C·A⁰·²/U⁰·⁹), so it varies with wall thickness and specimen type. Read it on the MTC against the formula, not against a table copied from another site.

PSL 2 Charpy (Table 8), pipe body, full-size, minimum average, J

Outside diameter≤ X60> X60–X65> X65–X70> X70–X80> X80–X90> X90–X100> X100–X120
≤ 508 mm (20 in)27272740404040
> 508–762 mm (20–30 in)27272740404040
> 762–914 mm (30–36 in)40404040405454
> 914–1219 mm (36–48 in)40404040405468
> 1219–1422 mm (48–56 in)40545454546881
> 1422–2134 mm (56–84 in)405468688195108

Standard test temperature is 0 °C (32 °F); lower temperatures are agreed on the order. Pipelines that need ductile fracture arrest (gas, CO₂) use Annex G values instead.

Dimensions and tolerances

API 5L allows any outside diameter and wall thickness inside Table 9; standard size combinations come from ASME B36.10M and ISO 4200. Use our and weight calculator for OD, wall and kg/m.

Diameter (Table 10, pipe body)

Specified ODSeamlessWelded
< 60.3 mm−0.8 to +0.4 mm−0.8 to +0.4 mm
60.3–168.3 mm±0.0075D±0.0075D
> 168.3–610 mm±0.0075D±0.0075D, max ±3.2 mm
> 610–1422 mm±0.01D±0.005D, max ±4.0 mm
> 1422 mmAs agreedAs agreed

Pipe ends (100 mm at each end) have tighter limits, e.g. ±0.005D max ±1.6 mm for welded pipe 168.3–610 mm.

Wall thickness (Table 11)

Wall tSeamlessWelded
≤ 4.0 mm (SMLS) / ≤ 5.0 mm (welded)+0.6 / −0.5 mm±0.5 mm
4.0–25.0 mm (SMLS) / 5.0–15.0 mm (welded)+15.0 % / −12.5 %±10 %
≥ 25.0 mm (SMLS) / ≥ 15.0 mm (welded)+3.7 mm or +10 %, −3.0 mm or −10 % (greater)±1.5 mm

Random lengths, plain-end pipe (Table 12)

DesignationMin each pipeMin average per order itemMax
6 m (20 ft)2.74 m5.33 m6.86 m
9 m (30 ft)4.11 m8.00 m10.29 m
12 m (40 ft)4.27 m10.67 m13.72 m
15 m (50 ft)5.33 m13.35 m16.76 m
18 m (60 ft)6.40 m16.00 m19.81 m
24 m (80 ft)8.53 m21.34 m25.91 m

Threaded-and-coupled 12 m pipe has a higher minimum of 6.71 m. Container shipments usually call for 11.8 m maximum; state it on the order.

Length, straightness, mass

ItemRequirement
Approximate length±500 mm
Straightness≤ 0.2 % of length; ≤ 3.2 mm in the last 1.5 m
Mass, each pipe+10.0 % / −3.5 % (special light sizes and A25: −5.0 %)
JointersOnly if agreed
Hydrotest hold≥ 5 s (SMLS, and welded D ≤ 457 mm); ≥ 10 s welded D > 457 mm

Out-of-roundness (Table 10)

Specified ODBodyPipe end (100 mm)
< 60.3 mm1.2 mm0.9 mm
60.3–168.3 mm0.020D (D/t ≤ 75)0.015D (D/t ≤ 75)
> 168.3–610 mm0.020D0.015D
> 610–1422 mm0.015D, max 15 mm (D/t ≤ 75)0.01D, max 13 mm (D/t ≤ 75)
D/t > 75, or D > 1422 mmPer orderPer order

Pipe-end diameter for D > 610–1422 mm: seamless ±2.0 mm, welded ±1.6 mm; for 60.3–168.3 mm: −0.4 to +1.6 mm.

Weld seam tolerances (9.13)

ItemPipeLimit
Radial offset of plate edgesSAW/COW, t ≤ 15 mm1.5 mm
Radial offsetSAW/COW, t 15–25 mm0.1t
Radial offsetSAW/COW, t > 25 mm2.5 mm
Inside flash heightHFW/LW≤ 1.5 mm; outside flash trimmed flush
Trim groove depthHFW/LW, t ≤ 4 / 4–8 / > 8 mm0.10t / 0.40 mm / 0.05t
Weld bead height, internalSAW/COW3.5 mm
Weld bead height, externalSAW/COW, t ≤ 13 / > 13 mm3.5 / 4.5 mm
Inside bead at pipe endsSAW/COW, first 100 mmGround to ≤ 0.5 mm
Outside bead at pipe endsSAW/COW, first 150 mmGround to ≤ 0.5 mm if ordered
Bead misalignmentSAW/COW, t ≤ 20 / > 20 mm3 / 4 mm

End finish (9.12)

PSL 2 pipe is plain end only. Plain ends with t > 3.2 mm are beveled 30° (+5°/−0°) with a 1.6 ± 0.8 mm root face unless another end prep is ordered (e.g. compound bevel for heavy wall, square cut for mechanical couplings). Threaded and coupled ends (Annex F couplings) are PSL 1 only.

Weight and hydrotest pressure for common sizes

API 5L mass per unit length: m = t (D − t) × 0.02466 kg/m (D, t in mm). Hydrotest pressure for plain-end pipe: P = 2 S t / D, where S is a percentage of the grade’s SMYS (Table 26): 60 % for D ≤ 141.3 mm, 75 % for 141.3–219.1 mm, 85 % for 219.1–< 508 mm, 90 % for D ≥ 508 mm (X42 and above). The standard does not require test pressure above 20.5 MPa for these grades, so 20.5 appears as the cap below.

NPSOD × WT, mmkg/mkg per 12 mTest P, X52, MPaTest P, X65, MPaTest P, X70, MPa
2″60.3 × 3.915.446520.520.520.5
3″88.9 × 5.4911.2913620.520.520.5
4″114.3 × 6.0216.0719320.520.520.5
6″168.3 × 7.1128.2633920.520.520.5
8″219.1 × 8.1842.5551120.220.520.5
10″273.1 × 9.2760.3172420.520.520.5
12″323.9 × 9.5373.8888718.020.520.5
16″406.4 × 9.5393.27111914.417.919.3
20″508.0 × 12.7155.12186116.220.220.5
24″610.0 × 12.7187.06224513.516.918.2
30″762.0 × 15.9292.54351013.516.918.2
36″914.0 × 19.1421.50505813.516.918.2
40″1016.0 × 19.1469.55563512.215.216.4
48″1219.0 × 22.2655.19786211.814.815.9

Values are calculated with the 47th-edition equations for plain-end pipe at standard test pressure. Full size range: , , weight calculator.

Hydrotest rules (10.2.6)

ItemRequirement
Every lengthTested; no leakage through body or seam
Hold time≥ 5 s SMLS and welded D ≤ 457 mm; ≥ 10 s welded D > 457 mm
RecordingRecording gauge or interlock per tester
Gauge calibration (new in 47th)Dead-weight tester; mechanical gauges every 6 months, electronic transducers every 12 months
Grade A/B cap17.0 MPa (D ≤ 88.9 mm), 19.0 MPa (D > 88.9 mm)
Alternative test pressure75 % SMYS (D ≤ 141.3), cap 50.0 MPa (D ≤ 406.4) / 25.0 MPa (D > 406.4)
Marking“TESTED” + pressure if above the standard value

Nondestructive inspection (Annex E; Annex K for sour/offshore)

ProductMethodExtent
HFW/EW weld seam (D ≥ 60.3 mm)Ultrasonic or electromagnetic100 % full length, full thickness
LW weld seamUltrasonic100 %
SAW weld seam (LSAW/SSAW)Ultrasonic (radiography by agreement)100 %, plus radiography of the weld for 200 mm at each pipe end
SSAW coil end weldUltrasonic100 %
PSL 2 seamless bodyUT / EMI / MT (Table E.2)100 % full length
PSL 1 seamless bodyAs aboveOnly if agreed (Q&T Grade B: mandatory)
Pipe-end laminations (25 mm zone)UT to ASTM A578/A435 or ISO 10893-8If ordered; rejects laminations > 6.4 mm circumferential
Body laminations, sour/offshoreUTAnnex K

NDT personnel are qualified to ISO 9712 or ASNT SNT-TC-1A; the 47th edition revised this certification clause.

Test frequency (Table 17 PSL 1, Table 18 PSL 2)

TestPSL 1PSL 2
Heat analysis1 per heat1 per heat
Product analysis2 per heat2 per heat
Body tensilePer test unit (25–50 t for small CW/HFW A25; same cold-expansion ratio otherwise)1 per 400 pipes (D ≤ 141.3), 200 pipes (141.3–323.9), 100 pipes (D > 323.9)
Weld tensile (D ≥ 219.1 mm)Per test unit1 per 200 pipes (≤ 323.9) / 100 pipes (> 323.9)
Guided bend (SAW)1 per 50 lengthsPer Table 18
CVN—Per test unit: 3 body; welded pipe also 3 weld + 3 HAZ
DWT—If agreed, welded D ≥ 508 mm
HydrotestEvery pipeEvery pipe

Inspection documents and MTC (10.1)

PSL 1PSL 2
CertificateOnly if agreed: EN 10204 3.1 or 3.2 (ISO 10474 3.1.A/B/C)EN 10204 3.1 mandatory; 3.2 (third-party witnessed) if ordered
ContentsOD, WT, PSL, type, grade, delivery condition; heat + product chemistry; tensile; hydro pressure and hold; NDT method and reference standard; weld-seam heat-treatment temperature; supplementary tests; mill names and locationsAll PSL 1 items plus CE value and limit, CVN results with specimen size and temperature, DWT results
Record retention≥ 5 years (47th edition)≥ 5 years

Every order ships with the producing mill’s EN 10204 3.1 or 3.2 certificate, passed on unaltered; where the order asks for 3.2, we arrange your nominated inspector (for example SGS, BV, TÜV, DNV or Lloyd’s) at the mill.

Coating and lining

API 5L covers bare pipe; temporary mill varnish is common unless the order says bare. Permanent coatings are bought to their own standards: 3LPE/3LPP to ISO 21809-1 or DIN 30670/30678, FBE to ISO 21809-2 or CSA Z245.20, concrete weight coating to ISO 21809-5, internal epoxy lining to API RP 5L2 (gas) or AWWA C210 (water). State cutback length and holiday test voltage on the order. See coated line pipe.

From design pressure to grade and wall (worked example)

Barlow: t = P D / (2 S F E T). For a gas line under ASME B31.8 Class 1 Division 2 (F = 0.72, E = 1.0, T = 1.0), 12.75 in (323.9 mm), MAOP 10 MPa:

GradeSMYSRequired tNext standard wallMass, kg/m
X42290 MPa7.76 mm8.38 mm65.20
X52360 MPa6.25 mm6.35 mm49.73
X65450 MPa5.00 mm5.56 mm43.65

Corrosion allowance, location class and code checks are added by the designer; higher grades cut tonnage but raise PSL 2 CE and toughness demands. Send the result to us as OD × WT × grade for a price.

Marking — how to read an API 5L stencil

Example from the 47th edition (USC units):

X API Spec 5L 20 0.500 X52M PSL 2 SAWL Y Z

FieldMeaning
XManufacturer name or mark
API Spec 5LStandard (plus “/ISO 3183” etc. if dual-certified)
20 0.500OD 20 in, wall 0.500 in
X52MGrade and delivery condition
PSL 2Product level (PSL2G if Annex G applies)
SAWLPipe type
Y, ZInspector mark; heat/lot ID linking to the MTC

Sour pipe adds S and the class: X52MSA. Offshore adds O. If the hydrotest pressure is above the standard value, “TESTED” and the pressure follow.

Sour service (Annex H) and offshore (Annex J) in numbers

Annex H chemistry, selected grades (Table H.1), % max

GradeCMnPSCEIIWCEPcm
X52NS0.161.650.0200.0030.430.22
X52QS0.161.650.0200.0030.390.20
X60QS0.161.650.0200.0030.410.22
X65QS / X70QS0.161.650.0200.0030.420.22
X52MS0.101.450.0200.002—0.20
X60MS0.101.450.0200.002—0.21
X65MS / X70MS0.101.600.0200.002—0.22

Also: Al ≤ 0.060 %, N ≤ 0.012 %, Cu ≤ 0.35 %, Ni ≤ 0.30 %, Cr ≤ 0.30 %, Mo ≤ 0.15 %, B ≤ 0.0005 %, Ca ≤ 0.006 % (Ca/S ≥ 1.5 for Ca-treated welded pipe). Seamless S may go to 0.010 %; seamless CEPcm may be 0.03 higher.

Annex H mechanical and HIC acceptance

ItemLimit
Max tensile Rm, BS–X52S625 MPa
Max tensile Rm, X56S / X60S / X65S / X70S640 / 670 / 685 / 720 MPa
YS/TS ratio (D > 323.9 mm)≤ 0.93
Hardness body, weld, HAZ≤ 250 HV10 (22 HRC); ≤ 275 HV10 at the 1.5 mm OD row if agreed, t > 9 mm
HIC (NACE TM0284), class ACSR ≤ 2 %, CLR ≤ 15 %, CTR ≤ 5 % (average of 3 sections)
Class L / FTest pH and H₂S partial pressure per order; other acceptance criteria may be agreed
SSC testFour-point bend to NACE TM0316 / ISO 7539-2 when ordered or for qualification

Annex J offshore hardness

GradeMax hardness body, weld, HAZ
≤ X65270 HV10 / 25 HRC
> X65–X80300 HV10 / 30 HRC
> X80325 HV10 / 33 HRC

Annexes buyers actually need to name

AnnexUse it whenWrite on the PO
BPSL 2 project with manufacturing procedure qualification“Annex B MPQT required”
GGas or CO₂ line needing fracture arrestArrest toughness or full-scale test basis
HSour service“Annex H, sour class A / L / F” (+ H₂S partial pressure and pH for F)
JOffshore“Annex J”
KNDT for sour/offshore/strainFollows H, J or N
NStrain-based design (seismic, reeling)Strain capacity requirements
MWelded jointersOnly if jointers are acceptable

API 5L PDF — where to get the standard

The legitimate source of the API 5L PDF is the API webstore (47th edition, 206 pages). Free “API 5L PDF” copies circulating online are usually old editions or unlicensed copies; they are not valid for contract or inspection use. This page gives the values buyers need for quoting; for the full text buy the standard. We send a one-page grade, PSL and tolerance summary with every quotation on request.

How to order API 5L line pipe (RFQ checklist)

Section 7.1 of the standard lists the mandatory order items; Section 7.2 lists more than 50 optional ones. A complete enquiry contains:

  1. Quantity (tonnes or metres) and delivery schedule.
  2. PSL 1 or PSL 2.
  3. Pipe type: SMLS, HFW (ERW), SAWL (LSAW) or SAWH (SSAW).
  4. Edition: API 5L 47th edition, or the edition your project specification names.
  5. Grade including suffix (e.g. X65M, X52N) — “X65” alone is incomplete for PSL 2.
  6. OD × wall (mm or in), e.g. 323.9 × 9.53 mm.
  7. Length: random (12 m / 40 ft) or approximate, and whether jointers are allowed.
  8. Annexes: H (with sour class A/L/F), J, G, N, B.
  9. Charpy test temperature if below 0 °C.
  10. End finish: standard bevel (see End finish above), a special bevel drawing, square cut, or threaded (PSL 1 only).
  11. Coating system and its standard (see Coating and lining above).
  12. Dual certification if needed (e.g. API 5L/ISO 3183, or API 5L Gr B/ASTM A106 B/A53 B for seamless).
  13. Inspection: EN 10204 3.1 or 3.2, third party (SGS, BV, TÜV), witness points.
  14. Destination port and Incoterm.

Missing items we see most: no grade suffix, no sour class, no edition, and Charpy temperature left blank.

Which Mejor Steel page fits your API 5L enquiry

You needPage
Seamless, NPS 1/2–24, heavy wall, Q gradesAPI 5L seamless line pipe
ERW/HFW, NPS 1/2–24, gathering and distributionAPI 5L ERW pipe
LSAW, 16–60 in, high-pressure transmissionAPI 5L LSAW pipe
SSAW, large OD water and low-pressure linesAPI 5L SSAW spiral pipe
A grade pageGrade B, API 5L X42 pipe, X52, X60, X65, X70, X80
Sour serviceSour service line pipe, NACE MR0175 guide
Corrosive fluidsCRA clad and lined pipe
API 5L vs A106API 5L vs ASTM A106

Larger or special size combinations: drawings and mill data supplied on request — get a quote.

API 5L vs ISO 3183 vs ASTM A106

API 5LISO 3183ASTM A106
ProductLine pipe, seamless and weldedLine pipe, same technical base as API 5LSeamless carbon pipe for high-temperature service
Quality levelsPSL 1 / PSL 2PSL 1 / PSL 2Grades A, B, C
Typical useOil, gas, water, CO₂ pipelinesSame, ISO-based projectsRefinery and plant piping
CharpyPSL 2 mandatoryPSL 2 mandatoryNot required by the base spec
Dual markingAPI 5L Gr B / ASTM A106 B / A53 B common for seamlessAPI 5L/ISO 3183 common—

Common API 5L mistakes on purchase orders

  1. Grade without suffix. “X52 PSL 2” can be delivered as N, Q or M — three different steels. Say which.
  2. “Sour service” without a class. Under the 47th edition the class (A, L, F) decides the HIC test solution.
  3. Old MTCs. A sour X65 certificate showing 720 MPa tensile does not meet the 47th-edition sour ceiling of 685 MPa.
  4. Copying elongation from a website. Minimum elongation depends on test-piece size; check it with the formula.
  5. Threads on PSL 2. Threaded ends are PSL 1 only.
  6. SSAW below 114.3 mm or LW above X70. Not permitted by Table 2.
  7. Leaving length open. Name the Table 12 designation and any container or site limit.

FAQ

What is the API 5L pipe specification?

It is the API product standard a pipe mill must meet to sell pipe as line pipe. It sets what is melted (chemistry), what the pipe must withstand (tensile, Charpy, hydrotest), how accurate it is (tolerances), how it is checked (NDT, test frequency) and how it is identified (marking, MTC). Its closest international counterpart is ISO 3183.

What is the latest edition of API 5L?

The 47th edition, published June 2, 2026. It replaces the 46th edition of 2018. The API Monogram effective date for the 47th edition is July 1, 2027.

What changed in API 5L 47th edition?

More than 15 topic areas, including sour classes A, L and F in Annex H, lower maximum tensile for sour X65 and X70, CO₂ pipeline requirements in Annex G, 5-year record retention, HFW weld quality, lamination UT, magnetic particle methods and hydrotest gauge calibration.

What is the difference between PSL1 and PSL2?

PSL 2 adds maximum yield and tensile, a yield-to-tensile ratio limit, mandatory Charpy testing, lower phosphorus and sulfur, carbon-equivalent limits, full weld NDT and full traceability. PSL 1 is the basic level.

What do the letters R, N, Q and M mean after an API 5L grade?

They show the delivery condition of PSL 2 pipe: R as-rolled, N normalized, Q quenched and tempered, M thermomechanical rolled or formed. S adds sour service and O offshore service.

What grades does API 5L cover?

PSL 1: A25, A25P, A, B, X42, X46, X52, X56, X60, X65, X70. PSL 2: B to X80 in R/N/Q/M conditions, plus X90 and X100 (Q seamless only, or M) and X120M.

What is the yield strength of API 5L X52?

Minimum 360 MPa (52,200 psi). PSL 2 X52 also has a maximum of 530 MPa and a tensile strength range of 460–760 MPa.

What size range does API 5L cover?

Outside diameters from 10.3 mm (0.405 in) to 2134 mm (84 in) in Table 9, with wall thickness up to 52 mm on the largest sizes. Helical-seam pipe starts at 114.3 mm.

Where can I download the API 5L PDF?

The licensed PDF is sold by API at apiwebstore.org. Free copies online are often old editions and are not valid for contracts. We send a buyer summary of grades, PSL and tolerances with quotations.

What information do I need to order API 5L pipe?

Quantity, PSL, pipe type, edition, full grade with suffix, OD × wall, length, annexes (sour class if Annex H), Charpy temperature, ends, coating, inspection certificate and destination port.

WhatsApp